Risperidone, Total
Ordering Info & Methodology
Test Code
Cerner Synonyms
RISPB
Risperidone Level
Turn Around Time
Methodology
Sunquest sites: 24hrs when received Sunday - Thursday.
Non-Sunquest sites: 3 days from receipt.
Liquid chromatography mass spectrometry
Ordering Guide
Panel includes Risperidone, OH-Risperidone, and Total Risperidone
Specimen Requirements
Sample Type
Collection Container
Alternate Collection Containers
Serum
Red
N/A
150 uL
7 days at 2 - 8 oC
Add on stability
This is the length of time after sample collection that this analyte is stable. Test can be added to a previously collected sample if the time since collection is less than the add on stability time.
Minimum Volume
Add On Stability
Collection and Shipping Requirements
Sunquest sites: Send on ice pack if shipped within 5 days of collection, otherwise send frozen.
Non-Sunquest sites: Send on ice pack if shipped within 3 days of collection, otherwise send frozen.
Reference Intervals
Female Reference Interval
Age Category | Reference Interval | units |
---|---|---|
Male Reference Interval
Age Category | Reference Interval | units |
---|---|---|
Additional Notes
[object Object]
Measurement Uncertainty (MU)
Every laboratory value is an estimate of the true concentration of substance. MU is the 95% confidence interval around that estimate. 95% of the time, the true concentration will be within the range of the reported value ±MU. This value is based on analytical variability (precision) and does not reflect other factors such as sample collection and handling which may also affect the result.
Example
Reported sodium = 140 mmol/L
Sodium MU = 1%
Expanded uncertainty = 140 mmol/L ± 1% or 140mmol/L ± 1.4 mmol/L
Interpretation - the true value of sodium in the sample is in the range 138.6-141.4 mmol/L, with 95% confidence.
Measurement Uncertainty
Ward should record information on dosage, date/time of last dose, and other meds. For therapeutic drug monitoring specimens must be drawn at trough.