top of page

Calcium Ionized Serum

Ordering Info & Methodology

Test Code

Cerner Synonyms

CAI

Ionized Ca Serum, iCa Serum, Calcium, Ionized, Free Calcium, Ionized Calcium, CA Ionized, Calcium Ionized

Turn Around Time

Methodology

Analyzed within 4 hours of receipt, 24/7. Available on a STAT basis.

Ion Selective Electrode, Radiometer ABL800

Ordering Guide

Specimen Requirements

Sample Type

Collection Container

Alternate Collection Containers

Serum

Gold

Heparinized Syyringe

2.0 mL

Cannot be added on to previously collected sample.

Add on stability
This is the length of time after sample collection that this analyte is stable. Test can be added to a previously collected sample if the time since collection is less than the add on stability time.

Minimum Volume

Add On Stability

Collection and Shipping Requirements

Refrigerate. Send on ice pack.

Reference Intervals

Female Reference Interval

Age Category
Reference Interval
units
0 y - <1 d
Not Established
mmol/L
1 d - <2 d
1.13-1.39
mmol/L
2 d - <3 d
1.19-1.43
mmol/L
3 d - <4 d
1.22-1.50
mmol/L
4 d - <5 d
1.27-1.52
mmol/L
5 d - <6 d
1.26-1.56
mmol/L
6 d - <2 m
1.32-1.59
mmol/L
2 m - <2 y
1.20-1.40
mmol/L
2 y - <20 y
1.20-1.35
mmol/L
≥ 20 y
1.17-1.29
mmol/L

Male Reference Interval

Age Category
Reference Interval
units
0 y - <1 d
Not Established
mmol/L
1 d - <2 d
1.13-1.39
mmol/L
2 d - <3 d
1.19-1.43
mmol/L
3 d - <4 d
1.22-1.50
mmol/L
4 d - <5 d
1.27-1.52
mmol/L
5 d - <6 d
1.26-1.56
mmol/L
6 d - <2 m
1.32-1.59
mmol/L
2 m - <2 y
1.20-1.40
mmol/L
2 y - <20 y
1.20-1.35
mmol/L
≥ 20 y
1.17-1.29
mmol/L
Additional Notes

[object Object]

Measurement Uncertainty (MU)
Every laboratory value is an estimate of the true concentration of substance. MU is the 95% confidence interval around that estimate. 95% of the time, the true concentration will be within the range of the reported value ±MU. This value is based on analytical variability (precision) and does not reflect other factors such as sample collection and handling which may also affect the result.

Example

Reported sodium = 140 mmol/L
Sodium MU = 1%
Expanded uncertainty = 140 mmol/L ± 1% or 140mmol/L ± 1.4 mmol/L
Interpretation - the true value of sodium in the sample is in the range 138.6-141.4 mmol/L, with 95% confidence.

5%

Measurement Uncertainty

Ionized calcium is corrected to a pH of 7.4. If the patient's pH is <7.2 or >7.6, this calculation is invalid and is not performed. Ionized calcium results in patients with these extreme blood pH values may be less reliable. It is suggested to correct the underlying acidosis/alkalosis and remeasure ionized calcium prior to performing further investigations or initiating therapy.

bottom of page