top of page

Testosterone Bioavailable Total Panel

Ordering Info & Methodology

Test Code

Cerner Synonyms

SHBGB

Sex Hormone Binding Globulin Level, Testosterone, Calculated Bioavailable, Calculated free testosterone, Bioavailable testosterone

Turn Around Time

Methodology

Analyzed within 4 days of receipt.

Calculated value

Ordering Guide

​

Specimen Requirements

Sample Type

Collection Container

Alternate Collection Containers

​

​

​

​

​

Add on stability
This is the length of time after sample collection that this analyte is stable. Test can be added to a previously collected sample if the time since collection is less than the add on stability time.

Minimum Volume

Add On Stability

Collection and Shipping Requirements

​

Reference Intervals

Female Reference Interval

Age Category
Reference Interval
units
0 y - <19 y
Not Established
nmol/L
19 y - <50 y
0.04-0.38
nmol/L
≥ 50 y
0.03-0.32
nmol/L

Male Reference Interval

Age Category
Reference Interval
units
0 y - <12 y
Not Established
nmol/L
12 y - <13 y
0.08-17.95
nmol/L
13 y - <14 y
0.32-19.07
nmol/L
14 y - <15 y
1.26-20.15
nmol/L
15 y - <16 y
3.39-21.17
nmol/L
16 y - <17 y
6.54-22.07
nmol/L
17 y - <18 y
8.53-22.83
nmol/L
18 y - <19 y
8.73-23.41
nmol/L
19 y - <20 y
7.24-23.82
nmol/L
20 y - <30 y
5.39-23.45
nmol/L
30 y - <40 y
4.92-18.63
nmol/L
40 y - <50 y
3.91-14.95
nmol/L
50 y - <60 y
3.12-12.61
nmol/L
60 y - <70 y
2.57-10.79
nmol/L
70 y - <80 y
2.54-9.75
nmol/L
≥ 80 y
2.66-8.94
nmol/L
Additional Notes

[object Object]

Measurement Uncertainty (MU)
Every laboratory value is an estimate of the true concentration of substance. MU is the 95% confidence interval around that estimate. 95% of the time, the true concentration will be within the range of the reported value ±MU. This value is based on analytical variability (precision) and does not reflect other factors such as sample collection and handling which may also affect the result.

Example

Reported sodium = 140 mmol/L
Sodium MU = 1%
Expanded uncertainty = 140 mmol/L ± 1% or 140mmol/L ± 1.4 mmol/L
Interpretation - the true value of sodium in the sample is in the range 138.6-141.4 mmol/L, with 95% confidence.

12%

Measurement Uncertainty

Bioavailable testosterone is calculated from the measured testosterone (LC-MS/MS) and the sex hormone binding globulin (Roche Cocas Immunoassay). As per MSP billing rules, sex hormone binding globulin and calculated bioavailable testosterone are not available unless testosterone falls between 4 and 10 nmol/L or is greater than 35 nmol/L.

 

bottom of page