Luteinizing Hormone
Ordering Info & Methodology
Test Code
Cerner Synonyms
LH
LH, Luteinizing Hormone, Interstitial Cell Stimulating Hormone, Leuteotropic Hormone, Luteotropic Hormone, Pituitary Gonadotropins, Luteinizing Hormone (LH)
Turn Around Time
Methodology
Analyzed within 4 days of receipt.
Sandwich immunoassay, electrochemiluminescence, Roche Cobas
Ordering Guide
Specimen Requirements
Sample Type
Collection Container
Alternate Collection Containers
Serum
Gold
Red
0.5 mL
Two weeks
Add on stability
This is the length of time after sample collection that this analyte is stable. Test can be added to a previously collected sample if the time since collection is less than the add on stability time.
Minimum Volume
Add On Stability
Collection and Shipping Requirements
Freeze. Send on ice pack.
Reference Intervals
Female Reference Interval
Age Category | Reference Interval | units |
---|---|---|
0 y - <7 y | See Comment(s) | IU/L |
7 y - <10 y | <0.8 | IU/L |
10 y - <13 y | <6.9 | IU/L |
13 y - <16 y | <23.1 | IU/L |
16 y - <18 y | <26.5 | IU/L |
≥ 18 y | See Comment(s) | IU/L |
Male Reference Interval
Age Category | Reference Interval | units |
---|---|---|
0 y - <7 y | See Comment(s) | IU/L |
7 y - <10 y | <0.8 | IU/L |
10 y - <13 y | <3.5 | IU/L |
13 y - <16 y | <5.7 | IU/L |
16 y - <18 y | 1.1-9.0 | IU/L |
≥ 18 y | 1.7-8.6 | IU/L |
Additional Notes
[object Object]
Measurement Uncertainty (MU)
Every laboratory value is an estimate of the true concentration of substance. MU is the 95% confidence interval around that estimate. 95% of the time, the true concentration will be within the range of the reported value ±MU. This value is based on analytical variability (precision) and does not reflect other factors such as sample collection and handling which may also affect the result.
Example
Reported sodium = 140 mmol/L
Sodium MU = 1%
Expanded uncertainty = 140 mmol/L ± 1% or 140mmol/L ± 1.4 mmol/L
Interpretation - the true value of sodium in the sample is in the range 138.6-141.4 mmol/L, with 95% confidence.
6%
Measurement Uncertainty
Assay interferences are possible in patients taking high dose (>5mg/day) biotin supplementation.